Syringe driver policy and safety

This is particularly important for patients receiving palliative care, for. Cc51 syringe driver guidance and standard operating procedures for adults in the usage of mckinley t34. All t34 ambulatory syringe pumps need a sponge pad fitted to. The procedure is designed to ensure that all registered nurses working for, or on behalf. Policy and protocol for the use of the cme mckinley t34. Subcutaneous drug infusion compatibility guidelines. Syringe images, syringe transparent png, free download. Syringe driver guidelines page 4 72810page 4 of 29 indications for use the graseby ms16a syringe driver is a portable, batteryoperated device, for mechanically delivering drugs at a predetermined rate. Adapted, with kind permission from nhs lanarkshire keywords minimum of 5. Good levels of knowledge concerning syringe driver use has been found among gps and community nurses, although this is not the case in some nursing home teams. Discard the needle immediately in a puncture resistant, leakproof sharps container. For many patients the setting up of a syringe driver is a response to unrelieved symptoms. Syringe driver drug compatibilities practice guidelines 2016 eastern metropolitan region palliative care consortium victoriaclinical working party 3. Ambulatory syringe driver care bundle to be implemented in conjunction with ambulatory syringe driver policy.

Graced by names such as graseby, well known for their modesty and ease, our syringe drivers will definitely impress you. This policy is not a stand alone document and is intended to be used in conjunction with the protocol and training pack for this device. Squeeze plunger release lever b on the syringe plunger driver and pull gently to extend it all the way. The policy covers how to use a syringe driver for palliative care patients. It sets out a number of principles and always events that should take place when setting up and taking care of a person and their family with a syringe driver. Ensure the syringe is labelled before placing the syringe within the syringe driver.

Easytouch fliplock safety syringes offer an easy and simple solution in caregiver protection. Safe practice in syringe pump management nursing times. This is because the niki t34 syringe driver simplifies administration by detecting the syringe size and volume of medicine, and sets the rate to deliver the infusion over the required time period, e. Syringe drivers should be serviced annually and dated. Syringe driver policy mersey care nhs foundation trust. We combine sophisticated technologies with easeofuse to facilitate improved patient outcomes. The use of a syringe driver for subcutaneous infusion allows several symptoms to be relieved via one route of administration and avoids the. All forms to print royal cornwall hospitals nhs trust. Slide 1 sc administration of medications using a syringe. The driver would then calculate the exact volume and a rate would be set in mlh. Syringe pumps offer an alternative route for delivering medicine when the oral route cannot be used. This policy is designed to support the administration of subcutaneous drugs, using a syringe driver by registered nurses working in the community setting.

The alaris pk syringe pump user interface has been developed in cooperation with leading european anaesthesiologists. A single drug, or more often a combination of drugs is given via a slow subcutaneous infusion to help control symptoms when other routes of administration are no longer viable, feasible or preferred. The change to mlh syringe drivers is a step in the right direction to improving the safety of syringe drivers. Terumos terufusion advanced infusion system offers more accurate and safer syringe pumps without putting an extra burden on the healthcare professional. Cc51 syringe driver guidance and standard operating. The policy provides the rationale for the use of the mckinley t34 syringe driver and guidelines to support staff training and management of associated equipment. Procedure for the use of syringe drivers january 2011 page 2 of 23 page 1. This policy identifies the principles and procedures for the management of subcutaneous infusions administered by syringe driver for adult supportive and palliative care keywords. The niki t34 syringe driver is a small, portable battery operated, programmable, ambulatory syringe pump that delivers the contents of a 2 to 50ml syringe over a specified duration of time or at a given rate in millilitres per hour mlhr. Procedure for the use of mckinley t34 syringe driver to deliver a continuous subcutaneous infusion in palliative care for adults page 8 of 41 9.

Policies lincolnshire community health services nhs trust. Example a syringe driver dose converting from oral morphine to syringe driver e. Health and safety policy on manual handling including bariatric policy. Procedure for the use of mckinley t34 syringe driver to. Types of syringe pumps there are two broad types of pumps. Clinical policy and procedure for the subcutaneous. Ensure breakthrough dose remains at 16th of syringe driver dose. However, it needs the continued multidisciplinary approach of nurses, doctors and pharmacists to limit prescribing and administration errors. This revised edition of the the guidelines for subcutaneous infusion device management in palliative care takes account of the october 2007 withdrawal from sale in australia of the graseby syringe driver, a subcutaneous infusion device that was the major focus of the first edition. The national patient safety agency npsa alert december 2010, safer ambulatory syringe drivers, identified that while the majority of syringe drivers and pumps used in healthcare have rate settings in millilitres ml, some older types of ambulatory syringe drivers have rate settings in millimetres mm of syringe plunger travel. Safety communication focuses on slow flowing continuous type infusions. Risk assessment for enhanced care above level 2 care rounding cha3760. Sh cp 18 syringe driver policy for adult supportive and palliative care version 7 november 2018 contents section title page 1.

Syringe driver guidance and standard operating procedures. During office hours contact pharmacy or the palliative care team for advice. In our locality the cme mckinley t34 syringe pump was procured because it met the requirements listed above and has additional safety features. A safety syringe has a safety mechanism built into the syringe. Syringe drivers are defined as power driven devices that drive the plunger of a syringe at an accurately controlled rate to deliver medications10. National patient safety agency 2010 safer ambulatory syringe drivers. Continuous subcutaneous infusion in palliative care. Syringe driver procedure for the administrationof medicationvia a subcutaneousroute including use of mc kinley t34 syringe driver ect002989 0.

Mckinley t34 syringe driver guidelines for adult supportive. Mar 30, 2015 syringe pumps are a vital tool for administering medicine, especially in palliative care. Stabilisation secure the catheter and apply a sterile dressing per facility protocol. This clinical policy and procedure applies to all mersey care nhs foundation.

However, nurses must have training before using them to ensure patient safety. Guidelines for syringe driver management in palliative care developed by. Request for information under the freedom of information. Do not place the label over the syringe increments or at the end of the syringe.

In 2010, the national patient safety agency npsa issued the rapid response report safer ambulatory syringe drivers. Syringe driver policy for adult supportive and palliative care. Take steps to reduce the risks of rate errors while older designs of ambulatory syringe drivers remain in use. A syringe pump is a pump used to deliver precise and accurate amounts of fluid in highimpact research environments ranging in fields from chemistry to neuroscience. Syringe driver policy for adult supportive and palliative care version. Only 48% of the palliative care services had a policy on combining drugs in syringe drivers for administration by subcutaneous infusion and 34% had an upper limit on the number of drugs combined. To raise awareness of nmc key principles, legal implications and organisational policies regarding syringe driver use and promote the safety and wellbeing of all patients who require the administration of medications by a syringe driver. Guidelines for syringe driver management in palliative care. What to do and where to get advice if the syringe driver is not working properly, or symptoms are not controlled, e. Load the syringe onto the pump as illustrated, making sure the flange of syringe barrel is pressed or rolled. Sh cp 18 syringe driver policy for adult supportive and palliative care version 7 november 2018 syringe driver policy for adult supportive and palliative care 1. Gosport inquiry panel accused of nhs cover up over faulty. Syringe driver policy version number 2 page 5 of 18 policy date 31. However, nurses must have training before using them to ensure patient safety safe practice in syringe pump management.

Syringe driver policy derbyshire alliance for end of. Mckinley t34 syringe driver guidelines for adult supportive and palliative care version. Use only one type of syringe driver in each setting to prevent confusion which may lead to errors6, 8, 10, 18. Kent community health nhs foundation trust syringe driver policy version 2. The procedure is designed to ensure that all registered nurses working for, or on behalf of the trust, provide the optimal level of care to this patient group. Pdf the benefits and drawbacks of syringe drivers in. The use of the niki t34 syringe pump via the subcutaneous route is used extensively.

Zomorph 60mg 12 hourly 120mg 120mg3 40mg diamorphine subcutaneously via syringe driver over 24 hours 40mg key sc. Standard operating procedure for safety thermometer data collection. Download free syringe png images, mirror dental syringe for injection, syringe driver, syringe needle, syringe cartoon, syringe vector, injection syringe, cartoon syringe, hand painted syringe, safety syringe, syringe clipart. Southern hsc trust procedures for the use of syringe drivers. Policy for the use of the ambulatory t34 syringe driver in. The most common duration for a syringe driver is over 24 hours. Enhanced care level 3 and 4 and behaviour and psychological symptoms observation chart. Standard terufusion pumps simplify workflows without compromising safety and treatment. Their use as a method of drug delivery to control symptoms in palliative care is a common and accepted practice.

On some models, a sheath is placed over the needle or the needle retracts into the barrel following injection to protect healthcare workers and others from accidental needlestick injuries. T34 syringe driver policy for use in the palliative care. They can be used in hospital, in hospices and at home. After injection, just flip the protective shield over the needle until it clicks and locks in place. The use of the niki t34 syringe pump via the subcutaneous route is. By continuing to use this site, you consent to the use of cookies. Definitions that apply to the policy 6 summary, introduction, purpose and justification 1,2,3,4 78 duties within the organisation 5 911 training and competence 6 1112 monitoring compliance and effectiveness 7 12 links to relevant standards 8 references 9 14 appendices clinical guidelines for the use of the t34 syringe driver.

Request for information under the freedom of information act. Mar 04, 2019 all t34 ambulatory syringe pumps need a sponge pad fitted to the battery compartment to prevent battery connection issues mda20190. The advantages of newer devices, safety and efficacy of drug combinations, selection of diluent, and management of. Syringe driver policy version number 2 page 4 of 18 policy date 31. Syringe driver policy derbyshire alliance for end of life care. Oct 25, 2018 laura, palliative care cns at kingston hospital, teaching the correct operation of a t34 mckinley syringe driver. For further information, including about cookie settings, please read our cookie policy. Collaborate with internal team to develop policies and procedures utilize vendor knowledge to form best practices. Policy and protocol for the use of the cme mckinley t34 syringe driver for adults in palliative care policy no. Syringe pumps also known as syringe drivers are commonly used for people living with a terminal illness. Syringe drivers are small portable usually battery operated devices used in palliative care. A brief video demonstrating how to insert the saftintima subcutaneous infusion set. The purpose of this policy is to ensure that persons operating syringe driver do so in the safest possible manner to ensure that syringe drivers are safe and effective. It is used to deliver medication via the subcutaneous route over a calculated period of time providing a continuous level of medication.

Policy for the use of the ambulatory t34 syringe driver in adults receiving palliative andor end of life care in the university hospitals of leicester nhs trust page 6 of 31 committee. Care of a gastrostomy rig feeding tube post insertion. Graham f, clark d 2005 the syringe driver and the subcutaneous route in palliative care. Procedure for the use of mckinley t34 syringe driver to deliver a continuous subcutaneous infusion in palliative care for adults policy authors palliative care team kate hall accountable executive lead chief nurse approving body patient safety committee, drugs and therapeutic committee. Agree an end date to complete the transition between existing ambulatory syringe drivers and ambulatory syringe drivers with additional safety features as soon as locally feasible, and within five years of this rrr. Ensure that the organisational protocol is followed regarding priming of the line2, 69.

To assist policy search engine mckinley t34, mckinley, t34, syringe driver, syringe, palliative care. Squeeze plunger release lever b on the end of the syringe plunger driver and slip the end of the syringe. Jan 21, 2019 how to set up a mckinley syringe pump. When and how to use a syringe driver in palliative care. Kain project officer, centre for palliative care research and education professor patsy yates acting director, centre for palliative care research and education. When and how to use a syringe driver in palliative. They are a safe and effective way to give medicines for symptoms such as pain, nausea and vomiting, seizures, agitation and respiratory secretions. Aim purpose the use of a portable battery operated syringe driver for subcutaneous medications is now a wellestablished technique in palliative care. This is a video tutorial on how to prepare an iv medication for syringe pump administration. Evidencebased information on subcutaneous syringe driver from hundreds of trustworthy sources for health and social care. This clinical policy and procedure aims to provide for the patient, a standard level of care and competence from registered nursing staff, when they require the administration of drugs subcutaneously using a syringe driver. Jun 23, 2018 the government inquiry into the gosport deaths ignored evidence suggesting that cheap, faulty syringe drivers may be responsible for thousands of deaths across the uk, fearing a national scandal. Motor engagement with syringe driver plunger overcoming force overcoming the gap. Syringe driver guidance and standard operating procedures for.

This policy is intended to support the safe use of the mckinley t34 syringe driver by all registered nurses and applies to all trust staff in all locations including temporary employees, locums and agency staff. Morgan s, evans n 2004 a small observational study of the longevity of syringe driver sites in palliative care. Gp supplies offers the highest quality syringes to match your requirements and expectations at competitive prices. Syringe driver policy version number 2 page 8 of 18 policy date 31. If the syringe driver is past its due maintenance date, do not use and send for servicing, as per medical device policy if applicable, ask the patient to position hisherself in an appropriate. Guidelines for subcutaneous infusion device management in. Mckinley t34 syringe driver guidelines for adult palliative care. The company further enhanced its product for the u.